Smart Battery Best For Off-Grid
Jakiper 48V100Ah LiFePO4 battery pack designed as a serial product.
JK48V100 is basic model I JK48V100PRO is upgraded model.
Using 16S 3.2V 100Ah brand new grade A cells, with smart BMS built-in, LCD display for reading, PC software for setting & diagnose.
Basic model:
- Able to connect and communicate with PC.
- Able to read pack parameter setting and running signals.
- Able to adjust settings.
Professional model:
- Battery pack connect communication cable with inverter, communicate with inverter.
- Able to connect and communicate with PC.
- Able to read pack parameter setting and running signals.
- Able to adjust settings.
LCD Monitor
Communication
Rack Mountable
Adjustable Protection Parameter
Smart BMS
High Capacity
Unlimited Parallel
Lighter Battery
Smaller Size
JK48V100PRO Product Analysis

Specifications
The JK48V100PRO 100 AH LiFePO4 Jakiper Battery
Nominal Voltage | Nominal Voltage 51.2V (48V System) |
---|---|
Nominal Capacity | Nominal Capacity 100 Ah (Cell Average 107Ah) |
Dimension (LxWxH) | Dimension (LxWxH) 442x460x177mm |
Approx. Weight | Approx. Weight 48.5 Kg |
Capacity @ 20A | Capacity @ 20A >300 mins |
Energy | Energy 5120Wh(Factory test>5170Wh) |
Resistance | Resistance < 50mΩ |
Self Discharge | Self Discharge < 3% |
Cells | Cells 3.2V 100Ah Cells |
Recommended Charge Current | Recommended Charge Current 20 A |
Maximum Charge Current | Maximum Charge Current 100 A |
Recommended Charge Voltage | Recommended Charge Voltage 56(initial charge)-58.4 V (after 30 cycles) |
BMS Charge Cut-Off Voltage | BMS Charge Cut-Off Voltage > 58.4 V (or cell >3.7 V) |
Over Charging Protection Release | Over Charging Protection Release < 54 V (and cell <3.38 V) |
Balancing Start (During Charging Only) | Balancing Start (During Charging Only)Cell > 3.3 V & Voltage difference > 20mV |
Maximum Continuous Dishcarge Current | Maximum Continuous Dishcarge Current 100 A |
BMS Discharge Current High Warning | BMS Discharge Current High Warning 105 A |
BMS Discharge Cut-Off Current | BMS Discharge Cut-Off Current 110 A (7000ms) |
Low Voltage Warning | Low Voltage Warning 44.8 V ( 2.8 V/Cell*16) |
BMS Discharge Cut-Off Voltage | BMS Discharge Cut-Off Voltage <43.2 V (Or cell< 2.5 V) |
Over Discharge Protection Release | Over Discharge Protection Release >47.2 V ( and cell >2.9 V) |
Short Circuit Protection | Short Circuit Protection 350 μs |
Terminal Type | Terminal Type M8x4 (Positive x 2, Negative x 2) |
Output Terminal Torque | Output Terminal Torque 106 ~ 132 in-lbs ( 12 ~ 15 N·m ) |
Case Material | Case Material Steel |
Recommended Connection Wire | Recommended Connection Wire Busbar or 6 AWG |
Temperature Sensor Quantity | Temperature Sensor Quantity 6 pcs |
Discharge Temperature | Discharge Temperature – 4 ~ 158 °F ( – 20 ~ 70 °C ) |
Charge Temperature | Charge Temperature 32 ~ 158 °F ( 0 ~ 70 °C ) |
Storage Temperature | Storage Temperature – 23 ~ 95 °F ( – 5 ~ 35 °C ) |
BMS High Temperature Cut-Off | BMS High Temperature Cut-Off 158 °F ( 70 °C ) |
Reconnect Temperature | Reconnect Temperature 140 °F ( 60 °C ) |
Related Products
JK48V100 Product Analysis